Again like report 101, there are no indications who made this particular report.
It has to be stated, that the one responcible made a great mess out-off his job. So many names spelled incorrectly that the educational standard of this person must have been quite poor. On the otherhand, there are some details which you cannot find elswhere.
What to think of Lorentz instead of Lorenz. He might have had the famous Dutch scientist Lorentz in mind. But, all those involved in the radio industry must have known the difference for decades. The problems we are facing, is that we cannot rely on names. This is generally already a weak point of the Allied post-war reports generally; but this one constitutes the 'bloody limit'.
Keywords: Lorenz Berlin; Telefunken berlin; Siemens-Halske (S&H) Berlin; A.E.G. Clausthal-Zellerfeld; interview with Mr Hülster Poszweg Berlin-Zohlendorf (Postweg Berlin-Zehlendorf??) Dr. Steimel ..; Dr. Herringer Dr. Düring (should be Döringer!!!), Dr. Milch chemist ...; LS52 .. DS310 and DS 311 the investigator should have noticed their main difference which si the DS310 (acorn valve) made for 2 V filament whilst the DS311 is needing 12.6 V .. ; Dr. Wiegand, Dr. Statz, Dr. Herrmann.. Dr. Pülfrich (Pulfrich?) .. ; Dr. Hopner .. Dr. Fitz .. Dr. Lärba .. Dr. Brück in Paris??; LS 1500, RS 557 . RS 558 and RS 564 ... RS 258 .. RS 239 .. Dr. Hoffmann, Dr. Bogash .. Dr. Jacobi ... Dr. Mühlbauer Dr. Etzrodt Scholz Ganswindt .. Richter .. Dr. Kratz .. Hengstmann ..; RS 301 - RS 566 .. Dr. Ziegenbein - Dr. Kugel - Dr. Scharfernicht (Bildwandler) - Dr. Ahrens - Dr. Nestler; RS 237 - RS 391 - RS 351 - RS 329 - RS 261 - RS 254 - RS 260 - RS 217 - RS 259 - RS 255 - RS 250 - RS 2551 - RS 262 - RS 266 - RS 366 - RS 366A - RS 366 B - RS 301 - RS 300 - RS 364 - RS 507 - RS 257 - RS 263 - RS 566; RD12Tf molybdenum U-rods (plates) .. ; LD 5 - AS 1010 - LS 180 - Cato-getter - Ba-getter .. Dr. Hülster .. Zirconium ... Zirconium powder is supplied by Degusa .. ; .. glass-metal seals .. pressed glass feet with electrodes ... a kind on nonex ... ; LMT .. B-40 glass ... Dr. Düsing (Telefunken) ... Dr. Heschendorf (Hereaus) and Dr. Fuchsius (Härtel & Keitel) ... ; copper glass joints ... (Gundelachglas) ... RS 564 ... LS 180 (LS180) .. LS 600 (LS600) Heidelberggerät (Klein-Heidelberg Elefant???) ... AS 1010 (AS1010) ... Ceramic tubes!!! ... ; LS 50 (LS50) ... Dr. Wolf (Telefunken) ... ; 100 kW Sendetriode RS 566 (RS566) data .. ; Telefunken technischer Bericht Nr. SRöP/1/48 ... Bearbeiter Günter Wolf SRöP of 1946 ... ; AV 29 - 0049 Ausgabe 24.11.42 LS 50 (LS50) Daten; Data LS 1500 (LS1500) ... ; K.Ltd. 37-230/87808/8.48.
Please continue, or proceed with FIAT-CIOS-BIOS main page